Model MY300L×4 CO2 Supercritical Extraction Machine

Product Description

 

MODEL 1200L( 300L X 4 )

This model is very popular among buyers who have requirements for output.
It adopts Siemens PIC control system.
It operates 24 hours a day and can process about 2,800 kilograms per day.

 

NO

MAIN CONFIGURATION

PARAMETERS

1

Extraction Tank

Volume:300L×4, Max working pressure: 35MPa

2

Separation Tank

Volume:100L×3 , Max working pressure: 20MPa

3

Pump

CO2 high - pressure pump & carrier pump

4

Cooling System

Temperature range: 5°C - 10°C

5

Heating Exchange System

/

6

Purification System

/

7

CO2 Storage Tank

/

8

Safety Devices

Pressure gauge at high - pressure pump outlet over pressure protection; extractor, separator, evaporator, dry purifier and mixer have safety valve to keep safe of system

9

Temperature Control System

Temperature range: Room temperature - 75°C

10

Power Consumption

253KW

11

Installation size:

15000mm × 9000mm ×8500mm

12

User supplied

CO2, 3 phase power

Product Center